The COPS energy balance and turbulence network intended to measure all components of the surface energy balance including the both turbulent fluxes of sensible and latent heat as well as the long and shortwave
Several meteorological parameteres were measured at different stations run by FZK/IMK-TRO. Depending on the individual site i.e. wind direction, wind speed, global radiation, reflected irradiance, atmospheric
The energy balance stations run by FZK/IMK-TRO measured high-frequency (20 Hz or 32 Hz) eddy-covariance raw data with either a Solent R1012 (Gill Instruments Ltd.) sonic anemometer or a Young 81000 (R.
cops_nebt_ubt_flux: Eddy-covariance turbulence data from COPS energy balance and turbulence network stations run by University of Bayreuth during COPS 2007
The energy balance stations run by University of Bayreuth measured either high-frequency (20 Hz) eddy-covariance raw data with a CSAT3 (Campbell Scientific, Inc.) sonic anemometer and a LI-7500 (LI-COR
Surface layer scintillometer data derived from a Optical Energy Balance Measurement System OEBMS1 with a Scintillometer SLS20 system by Scintec AG at station UV1EG (Deckenpfronn). The system operated at
The two energy balance station run by Meteo-France/CNRM measured high-frequency (20 Hz) eddy-covariance raw data with a Solent-HS (Gill Instruments Ltd.) sonic anemometer and a LI-7500 (LI-COR Biosciences)
The energy balance station run by University of Bonn measured high-frequency (10 Hz) eddy-covariance raw data with a CSAT3 (Campbell Scientific, Inc.) sonic anemometer and a LI-7500 (LI-COR Biosciences)
The 9 m profile mast run by University of Bayreuth continuously measured profiles of the wind speed, the air temperature and the water vapor pressure above a corn field with a sampling frequency of 1 Hz
The energy balance stations run by University of Bayreuth continuously measured radiation and soil parameters over different land types with a sampling frequency of 1 Hz averaged to 1 min values within
cops_nebt_imk3etg_flux_d: Eddy-covariance turbulence data of the energy balance network (NEBT) operating during COPS 2007: station IMK3ETG (Linkenheim)
The energy balance station IMK3ETG (Linkenheim) measured high-frequency (32 Hz) eddy-covariance raw data with a Young 81000 (R. M. Young Company) sonic anemometer above the target land use type grain.
cops_nebt_ubt3etg_flux_d: Eddy-covariance turbulence data of the energy balance network (NEBT) operating during COPS 2007: station UBT3ETG (Fischerbach)
The energy balance station UBT3ETG near Fischerbach measured high-frequency (20 Hz) eddy-covariance raw data with a CSAT3 (Campbell Scientific, Inc.) sonic anemometer and a KH20 (Campbell Scientific, Inc.)
cops_nebt_imk2etg_flux_d: Eddy-covariance turbulence data of the energy balance network (NEBT) operating during COPS 2007: station IMK2ETG (Baden Airpark)
The energy balance station IMK2ETG (Baden Airpark) measured high-frequency (20 Hz) eddy-covariance raw data with a Solent R1012 (Gill Instruments Ltd.) sonic anemometer and a LI-7500 (LI-COR Biosciences)
cops_nebt_uv1eg_flux_d: Surface layer scintillometer data of the energy balance network (NEBT) operating during COPS 2007: station UV1EG (Deckenpfronn)
Surface layer scintillometer data derived from a Optical Energy Balance Measurement System OEBMS1 with a Scintillometer SLS20 system by Scintec AG. The system operated at a measurement height of 1.75 m
cops_nebt_imk1etg_flux_d: Eddy-covariance turbulence data of the energy balance network (NEBT) operating during COPS 2007: station IMK1ETG (Hornisgrinde)
The energy balance station IMK1ETG (Hornisgrinde) measured high-frequency (20 Hz) eddy-covariance raw data with a Solent R1012 (Gill Instruments Ltd.) sonic anemometer and a LI-7500 (LI-COR Biosciences)
cops_nebt_imk8t_flux_d: Eddy-covariance turbulence data of the energy balance network (NEBT) operating during COPS 2007: station IMK8T (Burnhaupt le Bas)
The energy balance station IMK8T (Burnhaupt le Bas) measured high-frequency (20 Hz) eddy-covariance raw data with a Solent R1012 (Gill Instruments Ltd.) sonic anemometer above the target land use type