WCRP PCMDI BADC WDCC
QC History for CMIP5/output1/CSIRO-BOM/ACCESS1-0/rcp85

QC Results are available at: http://cera-www.dkrz.de/WDCC/CMIP5/QCResult.jsp?experiment=CMIP5/output1/CSIRO-BOM/ACCESS1-0/rcp85

Status Explanation:
QCL2_started: QC Level 2 checks are ongoing.
QCL2_assigned: QC Level 2 is assigned to the experiment.
QCL3_started: QC Level 3 checks are ongoing.
QCL3_assigned: QC Level 3 is assigned to the experiment and the data is DOI published according to the DataCite regulations [http://datacite.org/]. This data, its basic metadata and its DOI are persistent.
QCL1: The data of the experiment is withdrawn and waiting for a QC Level 2 check restart.

Last Change Revision of QC L2 Status Comment
2016-02-19T13:43:46 2 QCL3_assigned QC Level set to QCL3_assigned (2016-02-19 13:43:46 UTC): doi:10.1594/WDCC/CMIP5.CSA0r8 [http://dx.doi.org/10.1594/WDCC/CMIP5.CSA0r8 ]; QC Level2 assigned at 2014-09-30 06:24:58 UTC: The qc results for ACCESS1-0 rcp85 experiment look fine! F2: The 3hrly data for the rcp's is requested for 2026-2045 and 2081-2100. The QC is interpreting the gap between 2046-2080 as missing, but this is expected. W47_5: Height dimension correctly reports near surface fields as diagnosed at 1.5m rather than 2m. W56_5: hfrunoffds was produced as a 2D field in an earlier version, causing this confusion in the QC of the newer 3D field. This is OK. F3200: suspect isolated replcated records occur rarely and are unlikely to be a problem. F400: suspect minimum values occur rarely and are unlikely to be a problem. F800: suspect maximum values occur rarely and are unlikely to be a problem.
2014-08-08T03:27:41 2 QCL2_started -
2014-08-08T03:27:41 2 QCL2_assigned QC Level2 assigned at 2014-09-30 06:24:58 UTC: The qc results for ACCESS1-0 rcp85 experiment look fine! F2: The 3hrly data for the rcp's is requested for 2026-2045 and 2081-2100. The QC is interpreting the gap between 2046-2080 as missing, but this is expected. W47_5: Height dimension correctly reports near surface fields as diagnosed at 1.5m rather than 2m. W56_5: hfrunoffds was produced as a 2D field in an earlier version, causing this confusion in the QC of the newer 3D field. This is OK. F3200: suspect isolated replcated records occur rarely and are unlikely to be a problem. F400: suspect minimum values occur rarely and are unlikely to be a problem. F800: suspect maximum values occur rarely and are unlikely to be a problem.
2014-02-05T11:42:01 1 QCL2_started -

Back to QC summary page...
This page is hosted at WDCC, please send technical inquiries to data@dkrz.de.